Quality · Test Reports

Numbers you can build on — tested, not claimed.

Eight accredited tests stand behind every Real Panel datasheet value — thermal, fire, structural and dimensional. Here is what each one measures, and the results our panels achieve.

0.022W/mK
λ Thermal · PUR
B-s1,d0
Fire class · PIR
±1mm
Thickness tol.
8
Accredited tests
Why it matters

Why Test Reports Matter

Sandwich panel test reports serve three critical functions on a construction project. Under the EU Construction Products Regulation (CPR 305/2011), products on the European market must have their essential characteristics determined by harmonized test methods.

01 · Regulatory

Building permits

Authorities require documented proof that cladding meets thermal, fire and structural codes. Test reports provide that evidence.

02 · Structural

Engineering design

Engineers need verified load-bearing values to design purlin spacings and supports. Declared values without test backing create liability.

03 · Risk

Insurance

Insurers assess fire risk on tested, classified performance — not marketing. Accredited reports are the basis for assessment.

All testing referenced here is performed according to harmonized European standards per EN 14509 requirements.

The methods

The 8 Key Performance Tests

Our test reports cover eight essential performance characteristics. For each: what it measures, why it matters, and the results Real Panel products achieve.

01 Thermal Conductivity (Lambda) EN 12667EN 12939

Measures The rate at which heat passes through the insulation core — lambda (λ) in W/mK. Lower lambda means better insulation.

Matters Lambda is the foundation of every U-value calculation. If tested lambda differs from the declared value, every thermal specification based on that panel is wrong.

Method A sample is held between two plates at different temperatures; heat flow is measured at steady state. The test needs temperature equilibrium — several hours per sample.

Core materialDeclared lambdaTest method
PUR0.022 W/mKEN 12667
PIR0.023 W/mKEN 12667
EPS0.035 W/mKEN 12667
Rockwool0.040 W/mKEN 12667

Turn these lambda values into a panel thickness with our U-value calculator, or compare cores with the panel selector.

Guarded hot plate apparatus measuring the thermal conductivity of a sandwich panel sample
Lambda is measured on a guarded hot plate — the tested value behind every U-value.
02 Fire Classification (Reaction to Fire) EN 13501-1EN 13823EN ISO 11925-2

Measures How the panel reacts to fire — combustibility, smoke production and flaming droplets. Expressed as a Euroclass rating (A1–F) with smoke (s1–s3) and droplet (d0–d2) sub-classes.

Matters Fire class determines which building types a panel may be used on. Multi-storey, public and commercial buildings typically require B-s1 or A-class. Incorrect specification creates life-safety risk and non-compliance.

Method The Single Burning Item (SBI) test exposes a full-size panel corner to a controlled fire; heat release, smoke and flame spread are measured over 20 minutes. Separate small-flame testing confirms basic ignitability.

ProductEuroclassSmokeDropletsSBI + small flame
PUR panelsBs2d0✓ Tested
PIR panelsBs1d0✓ Tested
EPS panelsE✓ Tested
Rockwool panelsA1 / A2s1d0✓ Tested
FibercementA2s1d0✓ Tested

For specifying fire performance by building type, see our fire-resistance solutions.

03 Compressive Strength EN 826

Measures The load a panel can bear perpendicular to its faces before the core crushes — in kPa.

Matters Determines whether panels can support foot traffic during installation and maintenance, point loads from equipment mountings, and snow loads on roofs.

Typical results — PUR / PIR: 100–150 kPa · EPS: 60–100 kPa · Rockwool: 40–80 kPa (varies by density)
04 Tensile Strength (Adhesion / Peel) EN 14509 · Annex A

Measures The bond strength between the insulation core and the steel facings, tested by peeling the steel away from the core under controlled conditions.

Matters Poor adhesion lets a panel delaminate under wind suction or temperature cycling. The core-to-facing bond is what makes a sandwich panel a structural composite rather than three loose layers.

Result — bond strengths consistently exceed EN 14509 minimum requirements.
05 Shear Strength EN 14509

Measures The core's resistance to sliding failure when the panel is loaded in bending — it governs spanning capability between purlins.

Matters Engineers use shear data to calculate maximum purlin spacings and wind-load resistance. Under-specifying shear risks panel failure under extreme wind or snow events.

06 Flexural Strength (Bending) EN 14509

Measures The panel's resistance to bending under uniformly distributed loads — simulating wind pressure, snow load or self-weight across the span.

Matters Flexural data feeds directly into structural calculations for purlin spacing, span tables and load-bearing declarations.

Reference — span tables derived from these results are in our performance data.
Universal testing machine applying load to a sandwich panel sample in a structural laboratory
Compressive, shear and flexural strength are measured on a calibrated load frame.
07 Dimensional Tolerance EN 14509

Measures Accuracy of panel thickness, width, length and squareness against the declared nominal dimensions.

Matters Out-of-tolerance panels cause alignment problems, visible joint steps on facades, and air/water leakage at joints.

Result — ±1 mm thickness tolerance and ±2 mm length tolerance, verified in testing.
08 Water Vapor Permeability EN 12086

Measures The rate at which water vapor passes through the core — the water-vapor diffusion resistance factor (μ).

Matters In cold storage and high-humidity buildings, vapor permeability decides whether moisture can migrate into the core and condense, degrading insulation over time. PUR and PIR closed-cell cores have very high vapor resistance (μ > 30), ideal for moisture-critical applications.

For moisture-critical builds — see our cold-storage solutions.
All values

Test Results Summary by Product

Our complete test data in one reference table. Detailed values per product and thickness are in our performance data tables and the downloadable reports below.

TestPURPIREPSRockwool
Lambda (W/mK)0.0220.0230.0350.040
Fire classB-s2,d0B-s1,d0EA1/A2-s1,d0
Compressive (kPa)120–150120–15070–10050–80
AdhesionExceeds ENExceeds ENExceeds ENExceeds EN
Shear (kPa)80–12080–12050–8040–70
FlexuralPer span tablePer span tablePer span tablePer span table
Thickness tol.±1 mm±1 mm±1 mm±2 mm
Vapor resist. (μ)>30>3020–401–2
Cut sandwich panel test specimens lined up with calipers and gauges in a testing laboratory
Prepared test specimens — each tested result traces back to a measured sample.
Documents

Download Test Reports

All reports are available as PDF downloads. For product- or project-specific reports not listed, request them from our team.

Thermal Conductivity — EN 12667
PUR · PIR · EPS · Rockwool
PDFDownload
Fire Classification — EN 13501-1
PUR · PIR · EPS · Rockwool · Fibercement
PDFDownload
Compressive Strength — EN 826
All products
PDFDownload
Adhesion / Peel — EN 14509
All products
PDFDownload
Shear Strength — EN 14509
All products
PDFDownload
Flexural / Bending — EN 14509
All products
PDFDownload
Dimensional Tolerance — EN 14509
All products
PDFDownload
Water Vapor Permeability — EN 12086
PUR · PIR · EPS · Rockwool
PDFDownload
Questions

Frequently Asked Questions

What test reports are available from Real Panel?

Reports for all eight key characteristics: thermal conductivity (EN 12667), fire classification (EN 13501-1), compressive strength (EN 826), adhesion (EN 14509), shear strength, flexural strength, dimensional tolerance, and water vapor permeability (EN 12086) — all from accredited testing laboratories.

Are test reports needed for building permits?

Yes, in most markets. Authorities require documented proof of thermal performance (energy-code compliance) and fire classification (fire-safety approval). Our reports are accepted across Türkiye, Romania, Bulgaria, Georgia, North Macedonia and Kosovo. See our certificates page for the complete documentation package.

How often are sandwich panels tested?

Our quality policy requires batch testing during production (thickness, density, adhesion) plus periodic type testing at accredited laboratories for fire classification and thermal conductivity — so the reports reflect ongoing manufacturing quality, not one-time results.

Can I use Real Panel test reports for structural calculations?

Yes. The compressive, shear and flexural reports provide the input values engineers need for purlin spacing, wind-load resistance and snow-load design. Our performance data includes pre-calculated span tables derived from these results.

How do I download specific test reports?

Standard reports are available from the download section above. For product- or project-specific reports, contact our technical team — we prepare and deliver within one working day.

Need reports for a permit or a structural calc?

Tell us your product and project. We'll send the test reports you need — thermal, fire and structural — formatted for your authority or engineer, within one working day.