Technical · Reference

Sandwich Panel Performance Data

Sandwich panel performance data in one place — U-values, fire, acoustic and weight by core and thickness, for Real Panel facade, roof and cold room panels.

Facade · roof · cold room By core & thickness EN 14509
Reference tables

Sandwich panel performance data by core and thickness

Compare every Real Panel core across facade, roof and cold room applications. Each table lists the key declared values by panel thickness.

These tables are being finalised — declared values are added from Real Panel’s own test reports and certificates. For figures already available now, use the U-Value Calculator, the product datasheets, or request a value from our technical desk.
Facade Panels
PURPolyurethane Facade Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
400.0220.559.5B-s2,d025
500.0220.4410.0B-s2,d025
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
1200.0220.1812.5B-s2,d025
PIRPIR Facade Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
400.0220.559.5B-s2,d025
500.0220.4410.0B-s2,d025
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
1200.0220.1812.5B-s2,d025
EPSEPS Facade Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
500.0380.768.5E24
800.0380.479.0E24
1000.0380.389.5E24
1200.0380.329.5E24
1500.0380.2510.0E24
2000.0380.1911.0E24
ROCKWOOLRockwool Facade Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
500.0400.8013.5A2-s1,d030
800.0400.5016.5A2-s1,d031
1000.0400.4019.0A2-s1,d032
1200.0400.3321.0A2-s1,d033
1500.0400.2724.5A2-s1,d034
FIBERCEMENTFibercement Facade Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
500.0380.7615.0B-s1,d026
800.0380.4715.5B-s1,d026
1000.0380.3816.0B-s1,d026
1200.0380.3216.0B-s1,d026
Roof Panels
PURPolyurethane Roof Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
400.0220.559.5B-s2,d025
500.0220.4410.0B-s2,d025
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
PIRPIR Roof Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
400.0220.559.5B-s2,d025
500.0220.4410.0B-s2,d025
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
EPSEPS Roof Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
500.0380.768.5E24
800.0380.479.0E24
1000.0380.389.5E24
1200.0380.329.5E24
1500.0380.2510.0E24
ROCKWOOLRockwool Roof Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
800.0400.5016.5A2-s1,d031
1000.0400.4019.0A2-s1,d032
1200.0400.3321.0A2-s1,d033
1500.0400.2724.5A2-s1,d034
Cold Room Panels
PURPolyurethane Cold Room Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
1200.0220.1812.5B-s2,d025
1500.0220.1514.0B-s2,d025
2000.0220.1116.0B-s2,d025
PIRPIR Cold Room Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
600.0220.3710.0B-s2,d025
800.0220.2711.0B-s2,d025
1000.0220.2212.0B-s2,d025
1200.0220.1812.5B-s2,d025
1500.0220.1514.0B-s2,d025
2000.0220.1116.0B-s2,d025
EPSEPS Cold Room Panel
Thickness (mm)λD (W/m·K)U-value (W/m²K)Weight (kg/m²)Reaction to fireFire resistance (EI)Acoustic Rw (dB)
800.0380.479.0E24
1000.0380.389.5E24
1200.0380.329.5E24
1500.0380.2510.0E24
2000.0380.1911.0E24
How to read these tables

What each column means

Every value in these sandwich panel performance data tables is a declared or tested property of the panel. Lower U-values mean better insulation; reaction-to-fire and acoustic figures come from standardised tests.

λD — thermal conductivity
Declared conductivity of the core (W/m·K). The lower the λ, the better the core insulates for a given thickness.
U-value
Thermal transmittance of the whole panel (W/m²K) at that thickness — lower is better. Calculable from λD and thickness; see the U-Value Calculator.
Weight
Panel self-weight (kg/m²), used for structure, fixings and handling. Varies with core density and facing thickness.
Reaction to fire
Euroclass to EN 13501-1 (e.g. A2-s1,d0 or B-s2,d0). Mineral-wool cores reach the highest, non-combustible classes.
Fire resistance (EI)
Integrity/insulation rating in minutes to EN 13501-2, where the construction has been tested.
Acoustic Rw
Weighted airborne sound reduction (dB) to EN ISO 717-1, where tested.
Reference standards: panels to EN 14509 · U-value method to EN ISO 6946 · reaction to fire to EN 13501-1 · fire resistance to EN 13501-2 · acoustics to EN ISO 717-1.

Need a value that isn’t listed yet?

Tell us the panel, thickness and the property you need — U-value, fire class, weight or acoustics — and our technical desk sends the declared figure and the datasheet.