Rockwool Cold Room Panel

Non-combustible Rockwool cold room panel with stone wool (mineral wool) core, cam-lock assembly, and food-grade hygienic surfaces. The mandatory upgrade when fire safety regulations, insurance requirements, or high-value inventory require a non-combustible core in your cold storage.

  • Fire Classification: A2-s1, d0 (Euroclass) — very low smoke
  • Thermal Conductivity: 0.040 W/mK
  • Joint System: Cam-lock (eccentric hook) — airtight seal
  • Surface Finish: Food-grade white polyester or stainless steel
  • Thickness Range: 60 / 80 / 100 / 120 / 150 / 200 mm
  • Temperature Range: +15°C to -30°C

Standard fire rating sufficient? PUR cold room panel saves cost. Budget option: EPS cold room panel. Compare: Panel Selector.


Category


When Cold Storage Meets Fire Safety

The Rockwool cold room panel upgrades Real Panel’s proven cold room system with a stone wool foam core that achieves Euroclass A2-s1, d0 — a non-combustible A2 core — the highest reaction-to-fire class achievable in any cold room panel. Everything else remains identical to our PUR cold room panels: the same cam-lock joints, the same hygienic surfaces, the same temperature performance. The only difference is enhanced fire behavior where it counts.

Cold storage facilities present unique fire risks. Refrigeration systems use electrical components and compressors that can overheat. Ammonia-based cooling systems add chemical hazard. Insulated panels, by their nature, contain combustible foam. When fire reaches a cold room, rapid smoke generation in an enclosed space is extremely dangerous — both for personnel and for the stored products. Rockwool’s s1 (very low smoke) classification directly addresses this risk.

Key Benefits

  • Highest Foam-Core Fire Rating: A2-s1, d0 — the best fire classification achievable with a foam-core cold room panel. Rockwool’s self-charring mechanism slows fire spread and limits smoke generation.
  • Very Low Smoke in Enclosed Spaces: Cold rooms are sealed environments with limited ventilation. In a fire, s1 smoke classification means significantly less toxic smoke fills the space, giving workers more time to evacuate safely.
  • Insurance Compliance: Many food industry, pharmaceutical, and logistics insurers now require or require non-combustible A2 cold room panels. Specifying rockwool can reduce your annual insurance premium and ensure uninterrupted coverage.
  • Same Cam-Lock System: Identical eccentric hook joints with EPDM gaskets as PUR panels. Same airtight, vapor-tight seal. Same tool-free assembly. No learning curve for installation crews.
  • Thermal Trade-Off, By Design: Lambda 0.040 W/mK — higher than foam cores, so a rockwool cold room needs greater thickness for the same U-value. You trade a little insulation efficiency for non-combustibility, plus a useful acoustic bonus that foam cores cannot provide.
  • Regulatory Future-Proofing: Fire regulations for cold storage are tightening across Europe. Rockwool panels position your facility ahead of coming code changes, avoiding costly retrofits.

Manufactured at our production facility in Turkey. Available for domestic and export orders.

 

When to Choose Rockwool for Cold Rooms

  • Food & Pharma — meat processing, dairy, pharmaceutical storage where fire regulations are strict
  • Cold Storage Facilities storing high-value inventory (frozen food brands, medical products, expensive ingredients)
  • Ammonia-refrigerated facilities — where the combined risk of ammonia + fire demands enhanced panel fire performance
  • Insurance-mandated specifications — when your insurer requires or incentivizes A2-s1 rated panels
  • Multi-chamber cold rooms — where fire in one chamber must not compromise adjacent temperature zones
  • Export market projects — EU member states increasingly require A2-s1 for new cold storage construction

For standard cold storage where B-s2 is acceptable: PUR cold room panel. For budget cold rooms: EPS cold room panel.

Panel Specifications

SPECIFICATION VALUE
Core Material Non-combustible stone wool (rockwool), mineral fiber, open-cell
Core Density 100–110 kg/m³
Thermal Conductivity (λ) 0.040 W/mK (declared per EN 14509)
Panel Thickness 60 / 80 / 100 / 120 / 150 / 200 mm
Panel Profile Flat / smooth (both faces)
Effective Width 1150 mm (standard)
Maximum Length Up to 12,000 mm
Both Facings Pre-painted galvanized steel, 0.5–0.6 mm, white polyester (food-grade)
Optional Facings Stainless steel (AISI 304/316), plastisol, PVC laminate
Joint System Cam-lock (eccentric hook) with EPDM gasket
Cam-Lock Spacing Every 500–600 mm along panel edge
Fire Reaction A2-s1, d0 (Euroclass per EN 13501-1)
Smoke Classification s1 — very low smoke production
Weight (approx.) ~28–34 kg/m² (at 100 mm)
Operating Temperature +15°C to -30°C
Vapor Permeability Managed with a vapor barrier — open-fiber mineral wool core
Hygiene Food-grade, HACCP compatible
Floor Panel Option Available with reinforced facing
Standards EN 14509, CE Marked, ISO 9001, HACCP compatible

Recommended Thickness by Temperature

SPECIFICATION VALUE
+15°C to +5°C (chilled) 80–100 mm
+5°C to 0°C (fresh) 100–120 mm
0°C to -18°C (frozen) 120–160 mm
-18°C to -25°C (deep freeze) 160–200 mm
-25°C to -40°C (blast freeze) 200 mm

Calculate: U-Value Calculator.

U-Value by Panel Thickness

SPECIFICATION VALUE
60 mm U = 0.67 W/m²K
80 mm U = 0.50 W/m²K
100 mm U = 0.40 W/m²K
120 mm U = 0.33 W/m²K
150 mm U = 0.27 W/m²K
200 mm U = 0.20 W/m²K

Why Fire Risk Is Elevated in Cold Storage

Cold storage facilities face fire risks that standard commercial or industrial buildings do not:

  • Electrical systems: Refrigeration compressors, evaporator fans, defrost heaters, and control panels operate continuously. Electrical faults are the leading cause of cold storage fires.
  • Ammonia refrigeration: Large cold storage facilities often use ammonia as a refrigerant. Ammonia leaks combined with fire create toxic conditions that can be lethal.
  • Sealed environment: Cold rooms are designed to be airtight. In a fire, smoke has nowhere to go — it fills the enclosed space rapidly, reducing visibility to zero within seconds.
  • Limited access: Cold room doors are heavy, insulated, and often latched. Panicked workers may struggle to exit through doors designed to seal tightly.
  • Combustible contents: Packaging materials (cardboard, plastic wrap, wooden pallets) inside cold rooms provide significant fire fuel load.

How Rockwool Addresses These Risks

SPECIFICATION VALUE
Smoke Production A2 non-combustible: negligible smoke — maintains visibility in sealed cold rooms
Non-Combustible Stone wool does not ignite or add fuel load — it stops fire penetration at the panel
Fire Spread Non-combustibility limits lateral fire spread between cold room chambers
Toxicity Lower smoke volume = lower concentration of toxic combustion gases in enclosed space
Cost Premium 10–15% over PUR cold room panels — a fraction of potential fire damage costs

Insurance Perspective

Cold storage insurance is a specialized market where underwriters are acutely aware of fire risk. Key factors that influence your cold storage insurance premium:

  • Panel fire classification (A2-s1 rockwool vs B-s2 PUR can make a meaningful premium difference)
  • Refrigeration type (ammonia systems face higher scrutiny)
  • Detection and suppression systems (sprinklers, early warning)
  • Content value (high-value frozen goods increase exposure)
  • Building compartmentation (fire stops between chambers)

Discuss your cold room panel specification with your insurance broker before finalizing. For fire solutions across your entire facility: Fire Resistance Solutions.

How does the Rockwool cold room panel compare?

Feature Rockwool PUR EPS
Thermal (λ) 0.040 0.022 0.035
Fire Class A2-s1, d0 B-s2, d0 E
Smoke Very Low (s1) Low (s2) Moderate
Thickness for -25°C 155 mm 150 mm 220+ mm
Cost $$$ $$ $
Cam-Lock Yes Yes Yes
Insurance Premium savings Standard rate Higher rate (E)
Best For Fire-critical cold Standard cold Budget cold

Alternatives: PUR Cold Room · EPS Cold Room

Decide: Panel Selector.

Certifications

  • EN 14509: Self-supporting insulating panels.
  • CE Marking: European market compliance.
  • EN 13501-1: Fire reaction — Euroclass A2-s1, d0.
  • HACCP Compatible: Food-grade hygienic surfaces.
  • ISO 9001: Manufacturing quality management.

All certificates: Quality & Certificates.

What is the difference between rockwool and foam-core cold room panels?

Both use cam-lock joints, identical dimensions, and the same hygienic surface options. The core material differs: rockwool is non-combustible mineral wool (A2-s1, d0), while PUR is a combustible foam (B-s2, d0). Rockwool is the only cold room core that does not burn. Its lambda (0.040 W/mK vs PUR’s 0.022) is higher, so a rockwool cold room needs greater thickness for the same U-value — the trade-off for non-combustibility, plus an acoustic bonus. Choose rockwool when codes, insurers, or risk management require an A-class core.

Is a non-combustible core required for food storage cold rooms?

Not universally, but increasingly so. EU regulations and national building codes are tightening fire requirements for food storage facilities, particularly large-scale distribution centers and facilities using ammonia refrigeration. Check your local regulations and insurance requirements. A non-combustible rockwool core positions your facility for current and future compliance.

Does rockwool affect cold room temperature performance?

Yes, modestly. Because stone wool’s lambda (0.040 W/mK) is higher than foam, a rockwool panel reaches a given U-value at a greater thickness — e.g. 150 mm rockwool ≈ U 0.27 W/m²K. Specify a thicker rockwool panel for equal performance (see the thickness table above); sized correctly, energy use stays on target while you gain non-combustibility.

Can I mix rockwool and foam panels in the same cold room?

Technically possible (same dimensions, same cam-lock system), but not recommended. Using different fire ratings on different walls creates compliance ambiguity. Specify rockwool consistently for the entire enclosure to ensure a uniform A-class classification.

What about ammonia refrigeration compatibility?

Rockwool panels are compatible with ammonia (R-717) refrigeration systems. The non-combustible A2 rating of rockwool is particularly relevant for ammonia cold rooms, where fires produce extremely toxic smoke. As an A2-s1 core, rockwool adds no fuel and minimal smoke, improving evacuation safety in ammonia-related fire incidents.

Can Rockwool cold room panels be relocated?

Yes. Same cam-lock disassembly/reassembly as PUR. Panels can be taken apart and rebuilt at a new location without damage.

Do you export Rockwool cold room panels?

Yes. Romania, Bulgaria, Georgia, Macedonia, Kosovo. Request a quote or visit Export Markets